Polyisocyanurate

Results: 125



#Item
91Heat transfer / Thermal protection / Chemistry / Building insulation materials / Building insulation / Sustainable building / Polyisocyanurate / R-value / Shield / Mechanical engineering / Chemical engineering / Insulators

FM 1-90 Mechanically fastened sinGle ply membrane systems ATTACHMENT DETAILS INSULATION/ COVER BOARD ForNEW insulation

Add to Reading List

Source URL: www.hpanels.com

Language: English - Date: 2013-06-14 14:03:12
92Heat transfer / Thermal protection / Architecture / Building engineering / Sustainable building / R-value / Building insulation / Polyisocyanurate / Roof / Mechanical engineering / Insulators / Chemical engineering

H U N T E R P A N E L S H-Shield HD

Add to Reading List

Source URL: www.hpanels.com

Language: English - Date: 2013-12-31 13:46:01
93Insulators / Building insulation materials / Heat transfer / Thermal protection / Building materials / Polyisocyanurate / Building insulation / Roof / R-value / Mechanical engineering / Chemical engineering / Construction

built-Up roofing membrane systems FM 1-90 modified bitumen membrane systems For insulation thickness 1.5" and greater (field attachment only)* INSULATION BOARD

Add to Reading List

Source URL: www.hpanels.com

Language: English - Date: 2013-06-14 14:02:53
94Heat transfer / Thermal protection / Building insulation materials / Chemistry / Building engineering / R-value / Building insulation / Polyisocyanurate / Thermal insulation / Insulators / Mechanical engineering / Chemical engineering

Microsoft Word - HP_Letterhead_R-Value Interpretation 2013.doc

Add to Reading List

Source URL: www.hpanels.com

Language: English - Date: 2013-12-11 13:11:27
95Building insulation materials / Architecture / Greenhouse gas emissions / Plastics / Polyisocyanurate / Polyurethanes / Global-warming potential / Thermal insulation / Global warming / Environment / Climatology / Heat transfer

CUSTOMER BULLETIN 1109 ISO-C1 Polyisocyanurate Insulation Energy Savings and Global Warming Potential (GWP) PURPOSE This Customer Bulletin is another in a series of white papers aimed at providing our clients, engineers,

Add to Reading List

Source URL: www.dyplastproducts.com

Language: English - Date: 2013-04-29 16:36:54
96Insulators / Thermal protection / Building insulation materials / Building materials / Polyisocyanurate / R-value / Thermal insulation / Building insulation / Foam / Mechanical engineering / Heat transfer / Chemical engineering

CUSTOMER BULLETIN 0909 ISO-C1 Polyisocyanurate Insulation Flame Spread and Smoke Development PURPOSE This Customer Bulletin is another in a series of white papers aimed at providing our clients, engineers, contractors, f

Add to Reading List

Source URL: www.dyplastproducts.com

Language: English - Date: 2013-04-29 16:36:54
97Chemistry / Chemical engineering / Mechanical engineering / Insulators / Heat transfer / Polyisocyanurate / Foam / Insulation / Isocyanate / Building insulation materials / Polyurethanes / Plastics

CUSTOMER BULLETIN[removed]POLYISOCYANURATE VS. POLYURETHANE INSULATION PURPOSE This Customer Bulletin is one in a series of white papers aimed at providing our clients, engineers, contractors, fabricators, and friends with

Add to Reading List

Source URL: www.dyplastproducts.com

Language: English - Date: 2013-04-29 16:37:02
98Insulators / Thermal protection / Heating /  ventilating /  and air conditioning / Building insulation materials / Pipe insulation / Polyisocyanurate / Building insulation / R-value / Vapor barrier / Chemical engineering / Mechanical engineering / Heat transfer

CUSTOMER BULLETIN[removed]A COMPARISON OF ISO-C1® POLYISOCYANURATE and FIBERGLASS INSULATION PURPOSE This Customer Bulletin is part of a series of white papers aimed at providing our clients, engineers, contractors, fabri

Add to Reading List

Source URL: www.dyplastproducts.com

Language: English - Date: 2013-04-29 16:37:00
99Insulators / Thermal protection / Building insulation materials / Heating /  ventilating /  and air conditioning / Pipe insulation / Building insulation / Vapor barrier / R-value / Polyisocyanurate / Mechanical engineering / Chemical engineering / Heat transfer

TECHNICAL BULLETIN[removed]POLYISOCYANURATE VS. CELLULAR GLASS IN LOW TEMPERATURE MECHANICAL INSULATION PURPOSE This Technical Bulletin is an update in our series of white papers aimed at providing our clients, engineers,

Add to Reading List

Source URL: www.dyplastproducts.com

Language: English - Date: 2014-04-10 14:32:04
100Building insulation materials / Insulators / Thermal protection / Polyurethanes / Insulation / Polyisocyanurate / Building insulation / Thermal insulation / Mineral wool / Mechanical engineering / Chemical engineering / Heat transfer

CUSTOMER BULLETIN 0409 ISO-C1 Polyisocyanurate Insulation Improved K-Factor/R-Factor PURPOSE This Customer Bulletin is another in a series of white papers aimed at providing our clients, engineers, contractors, fabricato

Add to Reading List

Source URL: www.dyplastproducts.com

Language: English - Date: 2013-04-29 16:37:02
UPDATE