OHMS

Results: 62



#Item
11

Western Electric 145A Test Set This test set was used to test subscriber lines from the customer premises, generally after repairs were made. It measures Volts, Ohms, loop current, loss as well as balance, power influen

Add to Reading List

Source URL: www.islandregister.com

Language: English - Date: 2004-02-03 09:43:47
    12

    No Load Load = - 91 Ohms Integrated and amplified PS-4.5B Geophone velocity response - dB vs 1 V / m/s

    Add to Reading List

    Source URL: bnordgren.org

    - Date: 2012-10-08 11:49:22
      13Radio spectrum / L band / Microwave / Radio frequency / X10 / X band / V band / K band / Ka band / Wireless / Technology / Telecommunications engineering

      APPLICATION NOTES GENERAL SPECIFICATIONS INSULATION RESISTANCE: Resistance greater than 2 Giga-ohms at 50 Vdc is required between the chassis and all switch terminals. SPECIAL TESTING: Is available upon request. Ple

      Add to Reading List

      Source URL: www.ducommun.com

      Language: English - Date: 2014-02-19 01:13:03
      14Electricity / Electrical wiring / Electrical engineering / Power cables / Earthing system / Ground / Soil resistivity / Test probe / Earth potential rise / Electromagnetism / Electrical safety / Electric power distribution

      FAQ ON EARTHING STANDARDSWhat minimum readings do we have to get for: a) Standalone RMU – maximum 10 ohms per electrode where 2 electrodes exist per

      Add to Reading List

      Source URL: westernpower.com.au

      Language: English - Date: 2014-05-23 01:01:20
      15Electronics manufacturing / Electrical components / Resistor / Electronic test equipment / Measuring instruments / Electronic engineering / Printed circuit board / Multimeter / Soldering / Technology / Electromagnetism / Electronics

      Assembly Guide Solid State Amplifier 2 x 35Watts RMS @ 4ohms 2 x 32Watts RMS @ 8 Ohms Required Power: 48V DC @ 2.1 Amps

      Add to Reading List

      Source URL: ubld.it

      Language: English - Date: 2014-05-12 20:04:19
      16Pipeline and Hazardous Materials Safety Administration / Industrial hygiene / Environmental law / Dangerous goods / Emergency management / Right to know / United States Environmental Protection Agency / Safety / Prevention / Health

      Microsoft Word - OHMS Strategic Plan FinalStrategic PlanA_B

      Add to Reading List

      Source URL: www.phmsa.dot.gov

      Language: English - Date: 2015-02-10 09:29:41
      17Autonegotiation / Ethernet over twisted pair / Duplex / IEEE 802.3 / Network switch / Ethernet / OSI protocols / Network architecture

      SAFETY The LanMaster 20 has internal circuit protection to prevent damage if plugged into typical telephone circuits. The protection circuit can withstand 48Vdc from a source impedance of 600 ohms for 15 seconds. When co

      Add to Reading List

      Source URL: www.psiber.com

      Language: English - Date: 2009-12-18 20:17:18
      18Electromagnetism / Antique radio / Bakelite / Horn / Vacuum tube / Crystal radio / Brass instrument / Loudspeaker / Microphone / Radio electronics / Electronic engineering / Technology

      HRSA Auction – The Rare, the Early, and the Unusual. Radiofest 2014 Prices realised, in bold type. 1. Geco ‘phone box: Mid-20s, w/2 heaphone sets, one good (GEC 4K ohms) $[removed]United One: 1924-5, rare Udisco one va

      Add to Reading List

      Source URL: hrsa.asn.au

      Language: English - Date: 2014-09-24 07:22:41
      19Electromagnetism / Antique radio / Bakelite / Horn / Vacuum tube / Crystal radio / Brass instrument / Loudspeaker / Microphone / Radio electronics / Electronic engineering / Technology

      HRSA Auction – The Rare, the Early, and the Unusual. Radiofest 2014 Prices realised, in bold type. 1. Geco ‘phone box: Mid-20s, w/2 heaphone sets, one good (GEC 4K ohms) $[removed]United One: 1924-5, rare Udisco one va

      Add to Reading List

      Source URL: www.hrsa.asn.au

      Language: English - Date: 2014-09-24 07:22:41
      20Electricity / Electrical wiring / Electrical engineering / Power cables / Earthing system / Ground / Soil resistivity / Test probe / Earth potential rise / Electromagnetism / Electrical safety / Electric power distribution

      FAQ ON EARTHING STANDARDS[removed]What minimum readings do we have to get for: a) Standalone RMU – maximum 10 ohms per electrode where 2 electrodes exist per

      Add to Reading List

      Source URL: www.westernpower.com.au

      Language: English - Date: 2014-05-23 01:01:20
      UPDATE