Back to Results
First PageMeta Content
Electrotherapy / Neuroprosthetics / Medical equipment / RNS System / Epilepsy / Neurostimulator / Vagus nerve stimulation / Transcranial magnetic stimulation / Medical device / Medicine / Neurotechnology / Neuroscience


NeuroPace® RNS® System PMA P100026 Summary of Safety and Effectiveness Data ____________________________________________________________________
Add to Reading List

Open Document

File Size: 447,44 KB

Share Result on Facebook

City

Mountain View / /

Company

Remote Monitor Application Software / NeuroPace Inc. / EMC / /

Country

United States / /

Currency

pence / /

Event

FDA Phase / /

Facility

Laboratory Studies / /

IndustryTerm

secure web browser / software verification testing / wireless radio testing / surgical tools / home-use monitoring device / treatment of epilepsy / imaging / data using telephone lines / Software development / implantable device / therapy for epilepsy / target site / product software requirement specification / electrical energy / therapeutic ultrasound diathermy device / Wireless co-existence testing / near metal detectors / /

MedicalCondition

patient experiences clinical seizures / Allergic reaction / lymphoma / headache / seizures / severe injury / coma / balance disorder / complex partial seizures / resective epilepsy / Mechanical shock / tonic-clonic seizures / influenza / partial onset seizures / head injury / upper respiratory tract infection / pain of skin / site infection / abdominal pain / nasopharyngitis / clinical epileptic seizures / Thermal shock / implanted material Lead migration Stroke Brain abscess / seizure / vomiting / epileptic seizure / epilepsy / Irritation / depression / pharyngitis / Flexural fatigue / status epilepticus / /

MedicalTreatment

neurosurgery / surgery / Electroconvulsive Therapy / radiation / electrical stimulation of the brain / adjunctive therapy / Diathermy / drug therapy / /

Organization

U.S. Securities and Exchange Commission / Federal Communications Commission / United Nations / FDA / /

Person

Wand / Unsafe / /

Position

physician / General / Programmer Application Software model 3302 / model / General Information Device Generic Name / Programmer / /

Product

DTR-300 Remote Monitor / P-01 / F-01 / Use The RNS® System / /

ProvinceOrState

California / /

TVStation

Wand / /

Technology

radiation / X-ray / ultrasound / microwave / mobile phones / Integrated Circuits / MRI / cellular telephone / dielectric / neurosurgery / radio frequency / /

URL

www.neuropace.com / /

SocialTag